Please also view our problem solving section and contact support if you have any specific queries.  We also provide a Question & Answer section on our product range.Application & Safety

Application:
For leaded or unleaded petrol. Use 20ml in large cars or 10ml in small cars.  Regularly maintain the cleaned fuel system with Fuel Set.
Safety:
This is a non toxic product. Common sense precautions should be observed. Contact with skin or eyes should be flushed with water.

To Top


Product: Exit Rust
Application:
Remove loose or flaky rust and contaminates such as chemicals, oils or salts by wire brush or high pressure water. Dampen prepared surface with fine spray of clean water. Apply undiluted Exit Rust using either brush, roller or conventional airless spray. Leave for 12 - 24 hrs (For heavier rust apply Exit Rust 50% diluted with water, 30 - 60 mins later apply Exit Rust undiluted. Allow 12 - 24 hours for conversion). Once converted clean surface to remove all black residual dust that may appear with water, allow to dry then apply paint.
Safety:
This is a non toxic product. Common sense precautions should be observed. Contact with skin or eyes should be flushed with water.

To Top


Product:Corro Dip
Application:
Clean off oil and grease with detergent. Dilute 1 litre of Corro Dip to 5 litres of water, and immerse the metal object for between 3 - 24 hours. Hot water works more quickly. After immersion for the required period rinse and let dry. Not suitable for zinc. Solution is reusable. Do not use in metal containers.
Safety:
This is a non toxic product. Common sense precautions should be observed. Contact with skin or eyes should be flushed with water.

To Top


Product: Exit Grease
Application:
Apply to heavy grease with a brush. Allow to penetrate for 1 minute and then hose off with a strong jet of water. Dependant on severity of soiled areas Exit Grease may be diluted to a strength of 1:50 in hot or cold water. Normal cleaning methods may be used. Exit Grease is ideal for workshop floors and walls, locos, motor transport sections, ship bilges, truck engine components, rolling stock, chassis and transmission systems and all mining plants.
Safety:
This is a non toxic product. Common sense precautions should be observed. Contact with skin or eyes should be flushed with water. Avoid inhalation of fumes.

To Top


Product: Lemosol
Application:
General cleaning: 1 part Lemosol to 100 parts warm water. Heavy Duty Cleaning: 1 part Lemosol to 50 parts warm water. Apply by hand spray, sponge, mopping or high pressure hose.
Safety:
This is a non toxic product. Common sense precautions should be observed. Contact with skin or eyes should be flushed with water.

To Top


Product: ACL Lubricant
Application:
For normal use. spray or brush on to area to be treated.Can also be used as a bath.
Safety:
This is a non toxic product. Common sense precautions should be observed. Contact with skin or eyes should be flushed with water. If swallowed do not induce vomiting. Avoid inhalation of fumes. Spillage's may be slippery.

To Top


Product: Big Wash
Application:
First hose all loose dirt and mud from vehicle or surface to be cleaned. Generally, for cleaning manually or by pressure washers, foam guns, steam cleaners, automatic scrubbers or car wash systems, dilute Big Wash to about 50mls per litre of water. For severe soil build up, greater concentrations (up to 50%) may be used. May be used at 5-10mls per litre of water as a general purpose cleaner for most hard surfaces. We recommend not to wash vehicle surface in full sunlight.
Safety:
This is a non toxic product. Common sense precautions should be observed.

To Top


Product: Tuf Wash
Application:
Apply Tuf Wash to the hands and massage into the skin allowing enough time to penetrate the pores of the skin and remove deeply ingrained dirt.   Tuf Wash can then be rinsed off with cold or warm water.
Safety:
Tuf Wash is a non-toxic product.  Sensible precautions should be observed.  If product contacts eyes, rinse thoroughly with water.

To Top


Product:Master Flow
Application:
Drain existing coolant and flush system with clean water thoroughly until discharge is clear.  Be sure to flush all residue from cooling system, before filling with Master Flow premix.  Master Flow provides engine protection and cooling performance for up to 480,000km, 6,000 hours or 4 years in a heavy duty diesel application.
Safety:
Master Flow is a Schedule 5 Poison.  Keep out reach of children.  Keep away from food, drink and animal feeding stuff.  When using do not eat, drink or smoke.  Do not empty into drains.  Wear suitable protective clothing.  For further safety information refer to the Material Safety Data Sheet.
Harmful if swallowed.  Irritating to eyes and skin.  Harmful to aquatic organisms.  Contact local authorities for correct disposal method.
If poisoning occurs contact a doctor or Poisons Information Centre 131126.  If swallowed, and if more than 15 minutes from a hospital, induce vomiting, preferably using IPECAC APF Syrup if available.

To Top


Product: Weld Guard
Application:
Weld Guard is applied by refillable trigger sprayer (or brush), to the metal surfaces to be welded.
Safety:
If swallowed, contact a doctor or poisons information centre. Do not induce vomiting, give glass of water. If in eyes hold eyes open, flush thoroughly with copious amounts of water for at least 15 minutes. Avoid inhalation of Weld Guard spray mist and fumes.

To Top


Product:Tribo Plus
Application:
Add Tribo Plus to system at 60 mls per litre of oil. After first application halve dosage rate at oil change intervals. Undiluted may be used with excellent results in machine shops. for general drilling, tapping, threading and broaching and for low or high speed lathe work.
Safety:
Common sense precautions should be observed. Contact with skin or eyes should be flushed with water. Contains no PTFE resins.

To Top


Product: Core Seal
Application:
Core Seal is suitable for sealing the pores in concrete, bitumen or brick paving to create a surface which prevents penetration of water, gas or air.  All grain authorities in Australia have approved the product for use on grain storage flooring.
Application Directions:
Core Seal penetrates directly into the surface coated, where its wet white film cures to a non visible satin finish.  For surfaces exposed to direct sunlight, a pigmented coating is recommended as a top coat over Core Seal.
Surface Preparation:
All surfaces must be cleaned with a high pressure water wash prior to application.
Application Method:
Core Seal can be applied using an airless spray, paint brush or broom.  A spreading rate of 6 sq metres per litre is recommended for normal concrete or bitumen.   The spreading rate will be dependent on the porosity of the substrate.  Excess material should not be left on the surface of the treated area.
Curing Time:
24 hours in a ventilated area.
Safety: Core Seal is a non toxic, non flammable product.  Sensible precautions should be observed:

  • Keep out of reach of children
  • Contact to the eyes or skin should be avoided, protective gear should be worn.
  • Avoid inhalation of mists by wearing a dust mask on application.
To Top


Product: Supa Seal
Application:
Supa Seal can be applied to grain silos, metal roofs and similar applications that require a protective coating.  It is also suitable for adequately etched aluminium surfaces.  Supa Seal has been evaluated by Curtin Consultancy Services, WA and  certified to be in conformance with Co-operative Bulk Handling specifications for grain silo sealing systems.
Recommended Film Builds:
As a sealing membrane for lap joins and gaps not exceeding 2mm in width 3000 microns wet film thickness (1500 microns dry film thickness).  As a heat reflective top coat 300 microns wet film thickness (150 microns dry film thickness).
Surface Preparation: 
All surfaces must be clean, sound and free of all contaminants such as from oils and release agents.
Application Method:
Apply using an airless spray with a minimum of two coats.
A spreading rate of 1.7 sq metres per litre corresponds to 300 microns dry film thickness assuming no loss.  Practical spreading rates will vary due to such factors as method and conditions of application and surface roughness.  May be applied at up to 1500 microns wet film thickness without sagging or running.
Curing Time:
Internally coated silos should not receive product for a minimum of two weeks after the coating has been applied.  The silo must be ventilated to allow the membrane to cure.
Environmental Conditions:
Application, drying and curing of Supa Seal should take place within a set range of conditions for a successful result, Minimum - 1OC, Maximum - 45OC.  The usage outside these limits may result in some form of adhesion or coating failure.  Do not apply if during application or drying the surface temperature is likely to fall within 3OC of dew point.
Safety: Supa Seal is a non-toxic, non-flammable product. Sensible precautions should be observed:

  • Keep out of reach of children
  • Contact to the eyes or skin should be avoided, protective gear should be worn.
  • Avoid inhalation of mists by wearing a dust mask on application.
To Top